상세 보기
Sensorless MPPT Considering Power Loss Factors for DPP Structure in Photovoltaic Generation System
- Lee, Hyunjae;
- Shon, Jingeun
WEB OF SCIENCE
0SCOPUS
2초록
This paper presents an effective maximum power point tracking (MPPT) method for photovoltaic (PV) panels without any voltage sensor in a PV differential power processing (DPP) system. If a fault occurs in the voltage sensor, errors will occur in all control methods, including MPPT, thereby reducing power production efficiency. Therefore, this paper presents an effective duty MPPT method that enables normal MPPT, even without the voltage sensor of the DPP converter used in the PV power generation DPP systems. The proposed method performs MPPT by analyzing the power-loss elements of the DPP converter to recalculate the effective duty cycle used for actual power transmission and reduce the voltage calculation error. The effectiveness of the proposed method is verified in simulations and experiments, and the average accuracy compared with the general P&O MPPT is found to be 98.65[%] on average even without the use of a voltage sensor.
키워드
- 제목
- Sensorless MPPT Considering Power Loss Factors for DPP Structure in Photovoltaic Generation System
- 저자
- Lee, Hyunjae; Shon, Jingeun
- 발행일
- 2024-05
- 유형
- Article
- 저널명
- IEEE Access
- 권
- 12
- 페이지
- 123114 ~ 123126
- 언어
- ENG
- 출판사
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- 발행국가
- 미국
- 분량
- 13 페이지
- ISSN
- E 2169-3536
P 2169-3536