Noise level and similarity analysis for computed tomographic thoracic image with fast non-local means denoising algorithm

  • Kim, B.-G.; 
  • Lee, Y.; 
  • Kang, S.-H.; 
  • Park, C.R.; 
  • Jeong, H.-W.
Citations

WEB OF SCIENCE

19
Citations

SCOPUS

27

초록

Although conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm which would preserve the edge information of objects better than conventional denoising filters. In this study, we obtained thoracic computed tomography (CT) images from a male adult mesh (MASH) phantom modeled by computer and a five-year-old phantom to perform both the simulation study and the practical study. Subsequently, the FNLM denoising algorithm and conventional denoising filters, such as the Gaussian, median, and Wiener filters, were applied to the MASH phantom image adding Gaussian noise with a standard deviation of 0.002 and practical CT images. Finally, the results were compared quantitatively in terms of the coefficient of variation (COV), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and correlation coefficient (CC). The results showed that the FNLM denoising algorithm was more efficient than the conventional denoising filters. In conclusion, through the simulation study and the practical study, this study demonstrated the feasibility of the FNLM denoising algorithm for noise reduction from thoracic CT images. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.

키워드

Computed tomography thoracic image; Denoising algorithm; Fast non-local means approach; MASH phantom; Noise analysis
제목
Noise level and similarity analysis for computed tomographic thoracic image with fast non-local means denoising algorithm
저자
Kim, B.-G.; Lee, Y.; Kang, S.-H.; Park, C.R.; Jeong, H.-W.
DOI
10.3390/app10217455
발행일
2020-11
유형
Article
저널명
Applied Sciences (Switzerland)
권
10
호
21
페이지
1 ~ 14