초록
Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ∼ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.
키워드
- 제목
- 소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량
- 제목 (타언어)
- Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions
- 저자
- 장범진; 남하윤; 신혜민; 윤동민; 이승국; 장인화; 김성철
- 발행일
- 2023-10
- 저널명
- 방사선기술과학
- 권
- 46
- 호
- 5
- 페이지
- 409 ~ 415