Compressive Strength Testing of Hybrid Concrete-Filled Fiber-Reinforced Plastic Tubes Confined by Filament Winding

Citations

WEB OF SCIENCE

18
Citations

SCOPUS

18

초록

In this study, an experiment on compressive strength of the hybrid concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) confined by filament winding was conducted to improve the longitudinal strength while considering the thickness of filament winding as a variable. A maximum error of 17% was observed when the results of performing the finite element analysis (FEA) by applying the mechanical properties of the fiber-reinforced polymer (FRP) materials suggested in previous studies were compared to those of the compressive strength experiment on the hybrid-CFFT. Moreover, a maximum error of 15% was exhibited when the results derived from the strength equation proposed by analyzing the compressive strength experiment were compared. Furthermore, the compressive strength of the hybrid-CFFT increased by up to 14% when the longitudinal compressive strength of the pre-tensioned spun high strength concrete (PHC) pile and concrete-filled tube (CFT) were compared. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.

키워드

Compressive strength; FEA; FRP; Hybrid-CFFT; Mechanical properties
제목
Compressive Strength Testing of Hybrid Concrete-Filled Fiber-Reinforced Plastic Tubes Confined by Filament Winding
저자
Kang, In-Kyu; Kim, Sun-Hee
DOI
10.3390/app11072900
발행일
2021-04
유형
Article
저널명
APPLIED SCIENCES-BASEL
권
11
호
7