The Profile of Early Sedation Depth and Clinical Outcomes of Mechanically Ventilated Patients in Korea

  • Hyun, Dong-gon
  • Ahn, Jee Hwan
  • Gil, Ha-Yeong
  • Nam, Chung Mo
  • Yun, Choa
  • ... Choi, Woo sung
  • 외 28명
Citations

WEB OF SCIENCE

4
Citations

SCOPUS

5

초록

Background: Current international guidelines recommend against deep sedation as it is associated with worse outcomes in the intensive care unit (ICU). However, in Korea the prevalence of deep sedation and its impact on patients in the ICU are not well known. Methods: From April 2020 to July 2021, a multicenter, prospective, longitudinal, noninterventional cohort study was performed in 20 Korean ICUs. Sedation depth extent was divided into light and deep using a mean Richmond Agitation-Sedation Scale value within the first 48 hours. Propensity score matching was used to balance covariables; the outcomes were compared between the two groups. Results: Overall, 631 patients (418 [66.2%] and 213 [33.8%] in the deep and light sedation groups, respectively) were included. Mortality rates were 14.1% and 8.4% in the deep and light sedation groups (P = 0.039), respectively. Kaplan-Meier estimates showed that time to extubation (P < 0.001), ICU length of stay (P = 0.005), and death (P = 0.041) differed between the groups. After adjusting for confounders, early deep sedation was only associated with delayed time to extubation (hazard ratio [HR], 0.66; 95% confidence interval [CI], 0.55- 0.80; P < 0.001). In the matched cohort, deep sedation remained significantly associated with delayed time to extubation (HR, 0.68; 95% CI, 0.56-0.83; P < 0.001) but was not associated with ICU length of stay (HR, 0.94; 95% CI, 0.79-1.13; P = 0.500) and in-hospital mortality (HR, 1.19; 95% CI, 0.65-2.17; P = 0.582). Conclusion: In many Korean ICUs, early deep sedation was highly prevalent in mechanically ventilated patients and was associated with delayed extubation, but not prolonged ICU stay or in-hospital death.

키워드

Deep SedationCritical IllnessMortalityCritical CareVentilatorCRITICALLY-ILL PATIENTSLONG-TERM MORTALITYUNPLANNED EXTUBATIONPROTOCOLADULTSTRIALLIGHT
제목
The Profile of Early Sedation Depth and Clinical Outcomes of Mechanically Ventilated Patients in Korea
저자
Hyun, Dong-gonAhn, Jee HwanGil, Ha-YeongNam, Chung MoYun, ChoaLee, Jae-MyeongKim, Jae HunLee, Dong-HyunKim, Ki HoonKim, Dong JungLee, Sang -MinRyu, Ho-GeolHong, Suk-KyungKim, Jae -BumChoi, Eun YoungBaek, JongHyunKim, JeoungminKim, Eun JinPark, Tae YunKim, Je HyeongPark, SunghoonPark, Chi-MinJung, Won JaiChoi, Nak-JunJang, Hang-JeaLee, Su HwanLee, Young SeokSuh, Gee YoungChoi, Woo sungLee, Keu SungKim, Hyung WonMin, Young-GiLee, Seok JeongLim, Chae-Man
DOI
10.3346/jkms.2023.38.e141
발행일
2023-05
유형
Article
저널명
Journal of Korean Medical Science
38
19
페이지
1 ~ 13