Clinical safety and effectiveness of the Genoss drug-eluting stent in real-world clinical practice

  • Youn, Young Jin; 
  • Lee, Jun-Won; 
  • Ahn, Sung Gyun; 
  • Lee, Seung-Hwan; 
  • Yoon, Junghan; 
  • ... Kang, Woong Chol; 
  • 외 15명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

4

초록

Background/Aims: The Genoss DESTM is a novel, biodegradable, polymer-coated, sirolimus-eluting stent with a cobalt-chromium stent platform and thin strut. Although the safety and effectiveness of this stent have been previously investigated, real-world clinical outcomes data are lacking. Therefore, the aim of this prospective, multicenter trial was to evaluate the clinical safety and effectiveness of the Genoss DESTM in all-comer patients undergoing percutaneous coronary intervention.Methods: The Genoss DES registry is a prospective, single-arm, observational trial for evaluation of clinical outcomes after Genoss DESTM implantation in all-comer patients undergoing percutaneous coronary intervention from 17 sites in South Korea. The primary endpoint was a device-oriented composite outcome of cardiac death, target vessel-related myocardial infarction (MI), and clinically driven target lesion revascularization (TLR) at 12 months.Results: A total of 1,999 patients (66.4 & PLUSMN; 11.1 years of age; 72.8% male) were analyzed. At baseline, 62.8% and 36.7% of patients had hypertension and diabetes, respectively. The implanted stent number, diameter, and length per patient were 1.5 & PLUSMN; 0.8, 3.1 & PLUSMN; 0.5 mm, and 37.0 & PLUSMN; 25.0 mm, respectively. The primary endpoint occurred in 1.8% patients, with a cardiac death rate of 1.1%, target vessel-related MI rate of 0.2%, and clinically driven TLR rate of 0.8%.Conclusions: In this real-world registry, the Genoss DESTM demonstrated excellent safety and effectiveness at 12 months among all-comer patients undergoing percutaneous coronary intervention. These findings suggest that the Genoss DESTM may be a viable treatment option for patients with coronary artery disease.

키워드

Drug-eluting stents; Percutaneous coronary intervention; Prospective studies; Registries; CORONARY-ARTERY-DISEASE; MULTICENTER; OUTCOMES; TRIALS
제목
Clinical safety and effectiveness of the Genoss drug-eluting stent in real-world clinical practice
저자
Youn, Young Jin; Lee, Jun-Won; Ahn, Sung Gyun; Lee, Seung-Hwan; Yoon, Junghan; Park, Jae Hyoung; Yoo, Sang-Yong; Kang, Woong Chol; Lee, Nam Ho; Kwon, Ki Hwan; Doh, Joon Hyung; Lim, Sang-Wook; Jang, Yang Soo; Jeon, Dong Woon; Heo, Jung Ho; Choi, Woong Gil; Cho, Sungsoo; Lee, Bong-Ki; Jeong, Hyonju; Hong, Bum-Kee; Choi, Hyun-Hee
DOI
10.3904/kjim.2023.129
발행일
2023-09
유형
Article
저널명
The Korean Journal of Internal Medicine
권
38
호
5
페이지
683 ~ 691