Evaluation of a 3.5-MW Floating Photovoltaic Power Generation System on a Thermal Power Plant Ash Pond

Citations

WEB OF SCIENCE

16
Citations

SCOPUS

18

초록

This study evaluated the design and performance of an improved 3.5 MW floating photovoltaic (PV) power generation system consisting of fiber-reinforced polymer (FRP) members and its installation in the ash pond of a thermal power plant. The FRP design code of the American Society of Civil Engineers was used to design the structure. The safety of the structure was then confirmed using a finite element analysis indicating that the induced stresses were less than the allowable stresses dictated by the Korean Highway Bridge Design Code. An examination of the energy performance of the floating PV energy generation system after installation determined that the measured electricity production was as high as approximately 94% of the installed 3.5-MW capacity. The energy production of the floating PV structure with the improved design and module angles was found to increase by 7.65 times.

키워드

floating photovoltaic; ash pond; finite element analysis; fiber-reinforced polymer member; DESIGN
제목
Evaluation of a 3.5-MW Floating Photovoltaic Power Generation System on a Thermal Power Plant Ash Pond
저자
Choi, Jung-Youl; Hwang, Seong-Tae; Kim, Sun-Hee
DOI
10.3390/su12062298
발행일
2020-03
유형
Article
저널명
Sustainability
권
12
호
6